Page 275 - Pages from 8. 2017 New 26-05-21 No Table- 2nd Half
P. 275

--

               1
               1 x Email
               me to Morgana about a pur 150 bookmaker I brought for the company!
               Date: Tuesday, 25 April 2017, 11:37
               Subject: To Mat in regards towards a Purr 150
               From: Rewired re_wired@ymail.com
               To: service@morgana.co.uk
               Dear Mike and Mat
               Hello how are you doing, I hope all is well I spoke to a gentleman on the
               24/04/2017
               on the phone called mike in regards to a Morgana pur 150 that I am interested in purchasing
               from another person, mike then passed the phone to a man called Mat, who then asked me to
               send this reply. The machine I am able to buy seems to come with its own problems and I
               request your help in solving the issues.
               Diagnostic; when the machine is first turned on it allows any user to go to the first stage
               which is; “Are you trained to operate this machine” once ticked in agreement the power to the
               machine will flip the main distribution power supply but does not blow the machines internal
               fuses.
               On a diagnostic of the problem you have to take the two covers of the back of the machine
               and bypass the safety mechanism for the hatch door being closed.
               Connected to the bottom of the glue station, to which you put the glue into is a thermostat,
               this thermostat has two additional wires connected into it.
               The marks on the thermostat states that it is a; Mfr. Part No.2455RC Thermostat, Solder Tag
               Termination, 0°C +260°C
               When disconnected and the machine is rebooted with power it will bypass to the second
               stage; “Main menu”
               Once into the main menu the machine goes into alarm mode in turn disabling its features.
               The features that seem to be disabled are the following:
               1.  milling station: -
               2.  Press carriage;
               On a further inspection towards the resolution of the error codes; they are labelled as follows:
               1.  007 Error movement of press: -
               2.  009 Cleaner not present: -
               3.  010 Temperature not ok: -
               4.  011 Execute present: -
               5.  019 Critical Temperature;
               My main concern at present other than getting the machine to work:] is the error showing 007
               error movement of press, as I hope that changing the thermostat will clear error 010, 019 and
               then once 009 has been addressed then 011 will no longer exist as a problem if 007 is fixed,
               thus repairing the machine. After speaking to another gentlemen a Morgana it was explained
               to me that I can attach a external power supply to the mill and after to the carriage to check
               the motors to them mechanism are functioning correctly, on an attempt to do this the mill
               motor had no issue of concern and is a straight forward motor to supply the power to, the mill
               has neutral and live inclusive of ground. When rerouting the mill, I disconnected N1- L1
               from Km21.01 within the fuse board to add the external power supply, with the mill motor
               activating. I then attempted to make the press carriage active and took the chain of the motor