Page 276 - Pages from 8. 2017 New 26-05-21 No Table- 2nd Half
P. 276
so the spindle can move freely, on revealing the wires behind the power plate cover to the
motor, for the power cables to be connected I noticed four wires;
1. One grey in colour: -
2. One brown in colour: -
3. One black in colour: -
And: -
4. A green ground wire.
I understood the brown cable to be L1 live and grey to be forward while black would be
reverse to the motor, so I connected the external power supply with the ground connected,
then: -
1. I connected L1 also from an external power supply to L1 in the motor and the
2. N1 to the grey cable and after to the black cable, when this was achieved you could hear
the carriage motor slightly hum with power but no movement of the motors Spindale.
When the machine is as standard as at present, if any user is to go through stage one and
“Tick yes you are trained to use this machine,” once at stage two if u press the two green
buttons at the front of the machine simultaneously, that person will hear a breaker click in the
back of the machines fuse box, this shows code: E21.01 and has three lights, the top light is
always active named supply and in consequence to the two green buttons being push together
R2 will become active, with no response from the press carriage motor.
My questions are:
1. Does Morgana sell used parts at a discount from new priced parts?
2. How much would a press carriage motor cost in any of them instances?
3. If I continue to do a further diagnostic of the press carriage motor, I will split the
differential gearing from the motor and attempt to run the motor from an external power
supply, once again in the hope of keeping cost down in aiding to fix the machine.
4. How much will Morgana supply the required thermostat for after vat?
5. How much will Morgana supply a press carriage motor without gearing attached?
6. How much will Morgana supply gearing for the press motor without the motor attached?
7. How much will Morgana sell the carriage motor and gearing together for?
While I was in the fuse box at the back of the machine I notice two more fuse controllers that
are not active with present Semiconductor High Voltage Glass Passivated Junction Rectifiers
the fuse board numbers are as follows; Km20.01 Km23.01 on further research of them empty
fuse slots, after reading the wiring schematics it states that the usage for them slots are as
follows:
1. KM20.01 = Main Enabling
2. 2Km23.01 = Heating Enable
Another question I have to ask for your response in is; should those two slots be without
fuses as they are at present?
I also would like to question whether u supply the glue and blue beans needed to operate the
machine and pricing if so, if not please can you help provide a supplier for such products?
If I resolve the issues the machine is faced with at present, I would like to order the flat end
screws needed to service the glue station so for the glue to get extruded through its correct
path at its optimal performance and therefore request the following price of them parts from
your self’s. I would appreciate any help or advice that you or your team members may have
in helping to get the Morgana pur 150 re-commissioned.
Many thanks and kind regards
Mr S. Cordell
2
The Enfield Gov / Email’s Issue: 04